HUDY Pocket Scale User Manual Thank you for purchasing the pocket scale. With normal care and proper treatment it will provide years of reliable service. Please read all operating instructions carefully before use. It may be necessary to calibrate the scale before the first use. PROPER OPERATION AND ENVIRONMENT. My Weigh MX Series Models User Manual. MX-300, 120, 300, 500, 500H Manuals & Troubleshooting. This happens with all digital scales. We design our scales to be as. View and Download Fast Weigh TS-50 user manual online. TS-Series digital pocket scale. TS-50 Scales pdf manual download. Also for: Ts-500, Ts-100. User Manual Thank you for purchasing our pocket scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service. Never load the scale with more than the maximal capacity. Over loading can permanently damage it!
Personal care manuals and free healthcare pdf instructions. Find the personal care product manual that you need at ManualsOnline. Free Scale User Manuals ManualsOnline.com. Mini Digital Pocket Scales is too many type and you may have no idea about such many type. Miniinthebox will help you search for Mini Digital Pocket Scales, guaranteeing you’ll find the best one for you here.If you still have some problem, you can also ask our salesman who are more professional in their sale field. Dec 19, 2017 The MH-Series Digital Pocket Scale Review Instructions And Unboxing DIY University. Review and unboxing of the MH-Series digital pocket scale. Westonetek Portable 500g Digital Scale.
US-STINGER - User Manual
Capacity: 500g x 0.1g - Weighing modes: g, oz, dwt, ct
Thank you for purchasing US-STINGER digital pocket scale.
Please read all operation instructions carefully before use.
Scales are precision instruments and should always be handled
with proper care. To ensure years of reliable service, keep these
simple tips in mind:
Do not exceed the scales maximum capacity. Overloading your scale
can permanently damage it!
Avoid exposure to extreme heat or cold. Scales perform best at normal
room temperature. If temperatures have changed dramatically,
recalibration may be necessary.
Allow your scale to warm up for 30-60 seconds before performing
calibration (if available).
Store your scale in a clean, dry location. Dust, dirt, and moisture can
accumulate on the weighing sensors and electronics causing inaccuracy
or malfunction.
Avoid using you scale in close proximity to strong radio wave emitting
devices such as computers, cash registers, and cordless phones.
Always weigh on a flat level surface, free from vibrations and drafts.
The corner of a room is usually the most stable.
Gently apply all items to be weighed. Do not drop items onto the
weighing platform.
Avoid dropping your scale. The warranty does not cover damage due to
rough treatment or overload.
I-
SCALE OPERATION
Always weigh on a flat horizontal surface.
Calibration may be required before weighing
1. Press [ON/OFF] to turn the scale on.
2. When power is turned on, all display segments appear on LCD for a
Xbox one s user manual pdf. few seconds and finally “0” will appear on the display.
3.
Select the weighing unit with [UNIT].
4. Press [UNIT] to select a weighing unit, eg. ‘‘g “,”oz’’,‘‘ozt”, “dwt”
Once the unit has been selected, the selected unit will be displayed to
the weight value.
Start weighing
If you do not use a container for weighing, Verify the reading is “0”, if not, press
[ZERO] to display “0”
Place objects on the weighing platform to weigh.
When the reading becomes stable, the stable weighing value is displayed.
If you use a container for weighing, Place an empty container on the Platform
Wait for the stability weighing value to be displayed and press [ZERO] to display
“0”.
Place the objects to be weighed in the container.
II- CALIBRATION
When to calibrate
Calibration may be required when it is initially installed, if the mini scale is
moved to a substantial distance. This is necessary because the weight of a mass
in one location is not necessarily the same in another location. Also, with time
and use, mechanical deviations may occur.
How to calibrate:
Before entering calibration mode, press [ON/OFF] to turn the power off.
Press [ZERO] first, and then Press [ON/OFF], while keeping pressing [ZERO], the
display will show the A/D value.
Calibration by weight
Wait for 3 seconds, Press [ON/OFF] the display will show “2Ero”, after 2
seconds, the display will show calibration weight value.
Place the calibration weight on platform. Wait for 3 seconds, then press
[ON/OFF], the display will show “CAL”, after 2 seconds, the displayed will return
to “PASS” and then return to A/D value, now calibration is finished.
Press [ON/OFF], turn off the power, press [ON/OFF] turn on the power again,
place the weight on the platform to make sure whether weighing is correct, if
not, repeat steps 2-5.
Return to weighing mode
Press [ON/OFF] to turn the power off.
Press [ON/OFF] again to turn on the power and the scale return to the weighing
mode.
V-TROUBLESHOOTING
The primary reasons for inaccuracy or malfunction are low batteries,
incorrect calibration, overload or operating on an unstable surface.
Please keep this in mind and maintain and operate your scale properly.
[
]
Low battery
[EEEE]
You are overloading the scale. Remove the excess load
immediately!
Tested to comply with FCC standards
Instructions US-ABSOLUTE
Thank you for purchasing our pocket scale. We are confident that with normal use and
proper treatment your scale will provide you with years of reliable service. Please read all
the operation instructions carefully before you use your new scale.
Display Messages:
• LO – Low battery; please change the batteries in the scale.
• OuEr- The load cell of the scale is being overloaded. You need to remove the
excessive weight from the scale immediately.
• UnSt – The scale is placed on an unstable surface, please move the scale to a
more stable surface.
• rCAL – the scale can not return to zero, please recalibrate the scale.
• CAL – This is the prompt for beginning the calibration process of your scale. You
will see this message when you press and hold the Cal button on your scale. Once
this message appears, you must release the button and follow the remaining steps
for calibrating your scale.
• PASS – you have successfully calibrated your scale, you are now able to use the
scale.
• FAIL – Calibration has failed, please make sure you have the scale on a stable
surface and that you are using the correct weight to calibrate the scale. Try to
calibrate the scale following the calibration instructions exactly.
US Balance Instructions:
ON/OFF FUNCTION
Place your scale on a flat and stable surface away from any electronic equipment that
may interfere with the scale. Press and release the ON/OFF button, wait until the display
shows “0.00” and the zero-stable sign “ ”, you may now place the object you want to
weigh on the platform. The scale can be read when the lock sign “ ” is shown in the
display.
TARE FUNCTION
Turn on the scale as described above, place the “tare item” on the platform, press the
“ZERO” button to zero out the display, when “0.00” appears on the screen you may now
place items on the scale to be weighed. Once you are finished weighing, remove all
objects from the scale, press the “ZERO” again to cancel the TARE FUNCTION.